Introduction
- HART
-
PROFIBUS DP/PA
Liquids
Measuring Principle Electromagnetic Product headline Volume flow meter with economic flange design for measurement of conductive liquids inbasic water / waste water applications
Sensor features S-DAT
Quick Set-Up
2 Totalizer
Bullet nose electrodes
Nominal diameter range DN 50...2400 (2"...90")
Max. measured error ±0.5%
±0.2% (optional)
Measuring range 0...162'000 m3/h (713'000 gal/min)
Max. process pressure PN10...16
Cl 150
Medium temperature range -20...+90°C (-4...+194°F) PTFE + Polyurethane liner -20...+80°C (-4...+176°F) Hardrubber liner
Degree of protection IP 67 (NEMA 4x)
IP 68 (Nema 6P)
Display/Operation Two line display with backlit
Push button
Outputs 4...20 mA
Pulse/Frequency
Status
Inputs Status
Digital communication HART
PROFIBUS DP/PA
Hazardous area approvals FM
CSA
More Products